8 Ways To Combat Ice Dams on a Toronto home

It's very important to understand that the ice build up shown below is usually the result of a heat loss problem in the attic. The heat loss through the ceiling and lack of proper ventilation need to be addressed.

Never let anyone tell you that installing new eavestroughs will have a significant impact on any ice issues you may experience with your home. A proper functioning eavestrough system is definitely an important part of the big picture that may help with this problem but new eavestroughs will not eliminate ice build up, if the heat loss problem isn't taken care of.



Properly functioning eavestrough is essential for proper rainwater management around your home. In a Toronto winter we are dealing with snow melting due to heat loss and that is a different story. Snow melting on the roof will refreeze on the roof edge and eavestrough no matter what condition it is in because of below zero temperatures.

Ways to combat ice:

1. Prevent heat escape through the ceiling by making sure there are no major gaps around light fixtures to let warm air into the attic. This is best done from the attic and is easy to see once the loose fill insulation is pulled back a bit. Use spray foam to seal any gaps.

2. Make sure the insulation is about 16 inches thick to provide about an R-50 insulation value. Ensure it's evenly spread and no bare spots which are often caused by people working in the attic to do electrical and not spreading the insulation back out properly after the work is completed. If you have old style potlights, have an electrician inspect them to make sure they are to code before covering over.

3. Ensure all bathroom vents actually vent directly outside the attic through the roof and not just laid into the soffit.

4. Visually inspect from the attic that the soffits on the home are actually providing fresh cold air. You should be able to see a clear path to the soffit in the form of a baffle attached to the underside of the roof. Often you can see daylight if their is a clear path to a vented soffit. If you plan on getting your attic blown in, ensure baffles are installed if needed to ensure the ventilation to the soffit is not compromised.

5. Ensure that there are enough vents at the peak of your roof to let any heat out.

6. Install heater cables on the roof edge , eavestrough and down pipe. Note that this will not deal with the root cause of the ice. This is just throwing more energy at a energy loss issue. However careful use is needed in some cases. Some houses would require a major renovation to get to the root cause of heat loss due to vaulted ceilings etc.

7. Remove the snow off the roof so it can not melt and cause problems. Some roof tops can be reached from the ground using a roof snow rake which is much safer then going up a ladder this time of year.

8. Inspect soffits from the exterior to ensure that most or better yet all of the soffits are perforated with little holes to let the attic breathe. Unfortunately many homes have a layer of plywood hidden under the aluminum soffit which ideally should be removed to allow for maximum ventilation. To determine this a piece of soffit will need to be partially removed to inspect. Most Toronto and GTA homes built before the 80s will have this plywood. It's there because wood was used to cover in the soffits back then, not aluminum. When the aluminum soffits were done at a later point to cover the old plywood, the installers normally did not remove it to save time. At the very least, make sure there is a 1 foot square hole cut in the old plywood every 8 feet. Every piece of new soffit should be perforated.

Are you interested in new eavestroughs, leafguard, soffit, fascia, insulation or LED lighting for your Scarborough, North York or Toronto home?  Visit our website at www.eavestrough.ca

Sunday, January 23, 2011

Why Do Downspouts Fill With Ice?

Iced up downspouts are often cause for concern. You may wonder if the ice is blocking the downspouts due to a blockage of some sort. While this can be a factor in some cases it's more than likely just frozen water. The snow on the roof melts off the roof due to heat loss through the attic. The melted snow then runs down into the downspout which is not heated by the roof or in direct sunlight. The water instantly turns back to ice creating an ice filled downspout.


Adding more downspout or larger downspouts are not effective strategies for solving this problem. They will ice up just the same as the problem downpipe. If you really want to solve this you have to go to the root cause which is generally a heat loss issue in the attic. If fixing the insulation or ventilation in the attic is not feasible due to money or logistic reasons then a heater cable traced down the pipe can be very effective to keep your pipes free of ice.



Here is a quick video of a Toronto home with no ice issues. The pipe stays free of ice and snow.



Visit our website at www.eavestrough.ca

Thursday, January 21, 2010

Heater Cable Tips

heater cable frozen downpipes downspouts ice dams
This is the time of year when we get a lot of calls about frozen downpipes and gutters. This winter there has not been a lot of snow in Scarborough and North York. The major ice dams of the previous 2 years are not happening. Still the bit of snow we have had and the warmer weather has been icing up some eavestroughs and downpipes.

Generally, ice is caused from an attic that is not ventilated or insulated properly. The sun hitting the roof tends to increase the problem as well. Especially, if the sun warms a part of the roof and the downpipe is around the corner in the shade. Unfortunately water melting of the warm roof will not go down a downpipe if the temperature of the pipe is below zero.

There are a couple of ways to tackle ice problems. Either by reducing the heat loss in the attic or adding a heater cable to melt off the ice that builds up. North Shore always recommends dealing with the root cause of of ice problems, which is the attic, if possible. However this can get fairly involved on some homes redoing the entire soffits, insulating and adding roof vents. It's not always in the budget or in the homeowner's plan for the home. A alternative is heater cables which can be a cost effective solution.

If the ice builds up on the roof then the roof must be heated along with the gutter and downpipe. If it is just an ice filled gutter or downpipe then the cables can be limited to this area. Cables must be installed with a proper ground fault plug that will require the services of a licensed electrician. This is code and required for safety. Proper installation is the key to a good working system.

In our areas of Toronto we rarely see a set that is properly installed. The biggest offences are not heating the downpipes all the way to the bottom, overlapping cables that are not designed to touch, using extension cords because the plug is too far from the heater cable and running the heated portion of the cable through a wall. All these issues can result in a poor working system or a fire hazard. Trust North Shore to do the install in the most professional way. Costs vary depending on the length of the cable and the level of difficulty in reaching the affected area. If you would like more information you can email me at darren@eavestrough.ca or visit our website at http://www.eavestrough.ca/





Sunday, October 25, 2009

Maximize attic ventilation

soffits for maximum attic ventilation Toronto
If you are considering new soffit on your home it's important to realize it has a critical role in the way your house functions. Properly vented soffit allows cool air to enter into your attic space reducing or eliminating ice dams in the winter. This is important in our climate in Scarborough and all of Toronto. Also it reduces cooling costs and greatly extends the life of your roof. This house had aluminum soffits which we removed to find a layer of plywood. This plywood must be removed before installing new vented aluminum soffit. The plywood is there from when these houses were built in the '50s and '60s. It no longer serves any purpose with the introduction of new aluminum products. The plywood is not of structural importance and is ok to remove. It does create some labour costs to remove but the benefits are great over the long term. We then inspect to make sure the fresh air can make it into the attic unobstructed. We can easily install rafter chutes to the underside of the roof deck, now that the plywood is out of the way. These chutes control the airflow into your attic and prevent any loose fill insulation from falling out onto the new vented aluminum soffits. You can check out a short video that will help explain things.




Check out our website www.eavestrough.ca for more information.